Grandstream HT–286 or 701 provisioning
Grandstream HT–286 Analog Telephone Adapter reset and programming provisioning
Restore Factory Default Setting
WARNING! Restoring the Factory Default Setting will DELETE all configuration information of the phone.
Step 1:
Find the MAC Address of the device. It is a 12 digits HEX number located on the bottom of the unit.
Step 2:
Encode the MAC address. Please use the following mapping:
0-9: 0-9
A: 22
B: 222
C: 2222
D: 33
E: 333
F: 3333
For example, if the MAC address is 000b8200e395, it should be encoded as
“0002228200333395”.
Step 3:
To perform factory reset:
- Pick up the headset. Dial “***” (3 times)
- Enter “99” and get the voice prompt “Reset”.
- Enter the encoded MAC address of the device.
- Wait for 15 seconds. The device will reboot automatically and restore to factory default setting.
NOTE: Factory Reset will be disabled if the “Lock keypad update” is set to “Yes”.
Program UsVox Provisioning
Step 1:
- Pick up the headset. Dial “****” (4 times)
- Enter “02” or dial “*” (1 Time) for HT-701 model
Make a note of the device IP.
To be able to log the phone connected to the Grandstream HT–286 or HT-701 model Analog Telephone Adapter need to be on hook position.
Step 2:
Open any internet browser, on the address field type the IP address of the device and press enter
Restore Factory Default Setting
WARNING! Restoring the Factory Default Setting will DELETE all configuration information of the phone.
Step 1:
Find the MAC Address of the device. It is a 12 digits HEX number located on the bottom of the unit.
Step 2:
Encode the MAC address. Please use the following mapping:
0-9: 0-9
A: 22
B: 222
C: 2222
D: 33
E: 333
F: 3333
For example, if the MAC address is 000b8200e395, it should be encoded as
“0002228200333395”.
Step 3:
To perform factory reset:
- Pick up the headset. Dial “***” (3 times)
- Enter “99” and get the voice prompt “Reset”.
- Enter the encoded MAC address of the device.
- Wait for 15 seconds. The device will reboot automatically and restore to factory default setting.
NOTE: Factory Reset will be disabled if the “Lock keypad update” is set to “Yes”.
Program UsVox Provisioning
Step 1:
- Pick up the headset. Dial “****” (4 times)
- Enter “02” or dial “*” (1 Time) for HT-701 model
Make a note of the device IP.
To be able to log the phone connected to the Grandstream HT–286 or HT-701 model Analog Telephone Adapter need to be on hook position.
Step 2:
Open any internet browser, on the address field type the IP address of the device and press enter
The login page will appear on the screen
The factory password “admin”
Go to “ADVANCED SETTING 2”
Go to “ADVANCED SETTING 2”
On “Configuration Server Path” field type: 208.89.104.51
Press “Update”
Press “Reboot”